DATASHEET

Physical Port

  • 24 10/100/1000BASE-T Gigabit RJ45 copper ports with 24-port IEEE 802.3bt PoE++ injector function
  • 2 10GBASE-T RJ45 interfaces with auto MDI/MDI-X function
  • 2 10GBASE-SR/LR SFP+ slots, compatible with 2500BASE-X and 1000BASE-SX/LX/BX SFP
  • RJ45 console interface for switch basic management and setup 

 

802.3bt Power over Ethernet

  • Complies with IEEE 802.3bt Power over Ethernet Plus Plus
  • Backward compatible with IEEE 802.3af /at Power over Ethernet
  • Up to 24 ports of IEEE 802.3af/IEEE 802.3at/IEEE 802.3bt PoE devices powered
  • 24 PoE ports with built-in 802.3bt PoE++ Type-4 90 W injector function 
  • Auto detects powered device (PD)
  • Circuit protection prevents power interference between ports
  • Remote power feeding up to 100 meters
  • PoE management
    • Total PoE power budget control
    • Per port PoE function enable/disable
    • PoE admin-mode control
    • PoE port power feeding priority
    • Per PoE port power limitation
    • PD classification detection
    • Temperature threshold control
    • PD alive check
    • PoE schedul
    • PoE extend mode supports power feeding at a distance of up to 200 meters
  • Intelligent PoE features
    • Temperature threshold control
    • PoE usage threshold control
    • PD alive check
    • PoE schedule

 

Layer 3 Features

  • IP dynamic routing protocol supports RIP, OSPFv2 and OSPFv3
  • IPv4/IPv6 hardware static routing
  • Routing interface provides per VLAN routing mode
  • IP interfaces (Max. 128 VLAN interfaces)
  • Routing table (Max. 128 static routing entries)

 

Layer 2 Features

  • Storm Control support
    • Broadcast/multicast/unknown unicast
  • Supports VLAN
    • IEEE 802.1Q tagged VLAN
    • Supports provider bridging (VLAN Q-in-Q, IEEE 802.1ad) 
    • Private VLAN Edge (PVE)
    • Protocol-based VLAN
    • MAC-based VLAN
    • Voice VLAN
    • GVRP (GARP VLAN Registration Protocol)
  • Supports Spanning Tree Protocol
    • IEEE 802.1D Spanning Tree Protocol (STP)
    • IEEE 802.1w Rapid Spanning Tree Protocol (RSTP)
    • IEEE 802.1s Multiple Spanning Tree Protocol (MSTP), spanning tree by VLAN
    • BPDU Guard
  • Supports Link Aggregation
    • 802.3ad Link Aggregation Control Protocol (LACP)
    • Cisco ether-channel (static trunk)
    • Maximum 26 trunk groups with 4 ports for each trunk group 
    • Up to 80Gbps bandwidth (full duplex mode)
  • Provides port mirror (many-to-1)
  • Port mirroring to monitor the incoming or outgoing traffic on a particular port
  • Loop protection to avoid broadcast loops
  • Supports G.8032 ERPS (Ethernet Ring Protection Switching)
  • Compatible with Cisco uni-directional link detection(UDLD) that monitors a link between two switches and blocks the ports on both ends of the link if the link fails at any point between the two devices
  • Link Layer Discovery Protocol (LLDP)

 

Quality of Service

  • Ingress Shaper and Egress Rate Limit per port bandwidth control
  • 8 priority queues on all switch ports
  • Traffic classification
    • IEEE 802.1p CoS
    • TOS/DSCP/IP precedence of IPv4/IPv6 packets
    • IP TCP/UDP port number
    • Typical network application
  • Strict priority and Weighted Round Robin (WRR) CoS policies
  • Supports QoS and In/Out bandwidth control on each port
  • Traffic-policing on the switch port
  • DSCP remarking 

 

Multicast

  • Supports IPv4 IGMP snooping v1, v2 and v3
  • Supports IPv6 MLD snooping v1 and v2
  • Querier mode support
  • IPv4 IGMP snooping port filtering
  • IPv6 MLD snooping port filtering
  • Multicast VLAN Registration (MVR) support

 

Security

  • Authentication
    • IEEE 802.1x port-based/MAC-based network access authentication
    • Built-in RADIUS client to cooperate with the RADIUS servers
    • TACACS+ login users access authentication
    • RADIUS/TACACS+ users access authentication
  • Access Control List
    • IP-based Access Control List (ACL)
    • MAC-based Access Control List
  • Source MAC/IP address binding
  • DHCP Snooping to filter untrusted DHCP messages
  • Dynamic ARP Inspection discards ARP packets with invalid MAC address to IP address binding
  • IP Source Guard prevents IP spoofing attacks
  • IP address access management to prevent unauthorized intruder

 

Management

  • IPv4 and IPv6 dual stack management
  • Switch Management Interfaces
    • Console/Telnet Command Line Interface 
    • Web switch management
    • SNMP v1, v2c, and v3 switch management
    • SSHv2, TLSv1.2 and SNMP v3 secure access
  • SNMP Management
    • Four RMON groups (history, statistics, alarms and events) 
    • SNMP trap for interface Link Up and Link Down notification
  • IPv6 IP address/NTP/DNS management
  • Built-in Trivial File Transfer Protocol (TFTP) client
  • BOOTP and DHCP for IP address assignment
  • System Maintenance
    • Firmware upload/download via HTTP/TFTP
    • Reset button for system reboot or reset to factory default
    • Dual images
  • DHCP Relay and DHCP Option 82
  • DHCP Server
  • User Privilege levels control
  • NTP (Network Time Protocol)
  • Network Diagnostic
    • ICMPv6/ICMPv4 remote ping
    • Cable diagnostic technology provides the mechanism to detect and report potential cabling issues
  • SMTP/Syslog remote alarm
  • System Log
  • PLANET Smart Discovery Utility for deployment management
  • PLANET UNI-NMS (Universal Network Management) and CloudViewer app for deployment management
  • Provides ONVIF for co-operating with PLANET IP surveillances
  • Smart fan with speed control

 

Redundant Power System 

  • Redundant 100~240V AC/36-60V DC dual power 
  • Active-active redundant power failure protection
  • Backup of catastrophic power failure on one supply
  • Fault tolerance and resilience

 

Powerful 802.3bt PoE Managed Switch with Advanced L2+/L4 Switching and Security

PLANET GS-6320-24UP2T2XV is a cost-optimized, 1.25 U, Gigabit 802.3bt PoE Managed Switch with LCD Touch Screen featuring PLANET intelligent PoE functions to improve the availability of critical business applications. It provides IPv6/IPv4 dual stack management and built-in L2+/L4 Gigabit switching engine along with 24 10/100/1000BASE-T 802.3bt PoE++ ports, 2 10GBASE-T RJ45 ports and 2 additional 10Gigabit SFP+ ports. With a total power budget of up to 720 watts for different kinds of PoE applications, the GS-6320-24UP2T2XV provides a quick, safe and cost-effective 802.3bt PoE network solution for small businesses and enterprises 

IEEE 802.3bt PoE solutions

The GS-6320-24UP2T2XV supports the 802.3bt standard, supplying up to 95 watts per port for increased requirements of devices. It can offer more PoE applications, such as:

  • PoE PTZ speed dome cameras
  • Any network device that needs higher PoE power to work normally
  • Thin-client
  • AIO (All-in-One) touch PC
  • Remote digital signage display

New Color LCD Touch Screen

The unique Smart LCD PoE Switch provides an intuitive touch panel on its front panel that facilitates the Ethernet management and PoE PD management. It greatly promotes management efficiency in large-scale networks, such as enterprises, hotels, shopping malls, government buildings, and other public areas, and features the following special management and status functions:

  • IP address, VLAN and QoS configuration
  • PoE management and status
  • Port management and status/SFP information
  • Troubleshooting: cable diagnostic and remote IP ping
  • Maintenance: reboot, factory default and save configuration

 

 

High Performance 10Gbps Ethernet Capacity

The GS-6320-24UP2T2XV offers wire-speed packets transfer performance without the risk of packet loss. The high data throughput of the device makes it ideal for most Gigabit environments. With a 20Gbps internal fabric and auto negotiation support in its 10 Gigabit port, the GS-6320-24UP2T2XV can handle extremely large amounts of data transmission in a secure topology linking to data center cloud computing, enterprise backbones, campus networks, and carrier infrastructure.

 

Convenient and Smart ONVIF Devices with Detection Feature

PLANET has newly developed an awesome feature -- ONVIF Support -- which is specifically designed for co-operating with Video IP Surveillances. From the GS-6320-24UP2T2XV GUI, clients just need one click to search and show all of the ONVIF devices via network application. In addition, clients can upload floor images to a switch and it allows you to deploy any surveillance devices for easier inspection and planning. Moreover, clients can get real-time surveillance’s information and online/offline status, and also allows PoE reboot control from GUI.  

 

Built-in Unique PoE Functions for Powered Devices Management

Being the managed PoE switches for surveillance, wireless and VoIP networks, the GS-6320-24UP2T2XV features the following special PoE management functions:

  • PD alive check
  • Scheduled power recycling 
  • PoE schedule
  • PoE usage monitoring

 

Intelligent Powered Device Alive Check

The GS-6320-24UP2T2XV can be configured to monitor connected PD (powered device) status in real time via ping action. Once the PD stops working and responding, the GS-6320-24UP2T2XV will resume the PoE port power and bring the PD back to work. It will greatly enhance the network reliability through the PoE port resetting the PD’s power source and reducing administrator management burden.

Scheduled Power Recycling

The GS-6320-24UP2T2XV allows each of the connected PoE IP cameras or PoE wireless access points to reboot at a specified time each week. Therefore, they will reduce the chance of IP camera or AP crash resulting from buffer overflow. 

PoE Schedule for Energy Saving

Under the trend of energy saving worldwide and contributing to environmental protection, the GS-6320-24UP2T2XV can effectively control the power supply besides their capability of giving high watts power. The “PoE schedule” function helps you to enable or disable PoE power feeding for each PoE port during specified time intervals and it is a powerful function to help SMBs or enterprises save power and money. It also increases security by powering off PDs that should not be in use during non-business hours. 

 

PoE Usage Monitoring

Via the power usage chart in the web management interface, the GS-6320-24UP2T2XV enables the administrator to monitor the status of the power usage of the connected PDs in real time. Thus, it greatly enhances the management efficiency of the facilities.

 

10GBASE-T and 10GBASE-X SFP Dual Media Interfaces for Diversified Bandwidth Applications

The GS-6320-24UP2T2XV has the capability to reach a high speed of 10Gbps over copper or fiber-optic cabling which helps to accelerate the performance of large data transmission. The built-in 10GBASE-T copper interfaces support 5-speed (10G/5G/2.5G/1G/100) auto-negotiation, and 10Gbps data transmission with the existing Cat6A/Cat7 UTP cabling, meaning the speed can be increased without costs. It can definitely give you the speed you demand and its Plug and Play makes installation easy.

The fiber-optic 10GBASE-X SFP+ interfaces support 3 speeds, 10GBASE-SR/LR, 2500BASE-X and 1000BASE-SX/LX, meaning the administrator now can flexibly choose the suitable SFP/SFP+ transceiver according to the transmission distance or the transmission speed required to extend the network efficiently.

 

Redundant AC/DC Power Supply to Ensure Continuous Operation 

The GS-6320-24UP2T2XV is particularly equipped with one 100~240 V AC power supply unit and one 36~60 V DC power supply unit to provide an enhanced reliable and scalable redundant power supply. The continuous power system is specifically designed to fulfill the demands of high-tech facilities requiring the highest power integrity. With the 36~60 V DC power supply, the GS-6320-24UP2T2XV is able to act as a telecom-level device that can be located in the electronic room. 

Environment-friendly, Smart Fan Design for Silent Operation

The GS-6320-24UP2T2XV features a 19-inch metal housing, a low noise design and an effective ventilation system. It supports the smart fan technology that automatically controls the speed of the built-in fan to reduce noise and maintain the temperature of the PoE switch for optimal power output capability. The GS-6320-24UP2T2XV is able to operate reliably, stably and quietly in any environment without affecting its performance.

 

Solution for IPv6 Networking

By supporting IPv6/IPv4 dual stack and plenty of management functions with easy and friendly-user interfaces, the GS-6320-24UP2T2XV is the best choice for IP surveillance, VoIP and wireless service providers to deploy the IPv6 network. It also helps the SMBs to step in the IPv6 era with the lowest investment but not necessary to replace the network facilities while the ISPs construct the IPv6 FTTx edge network.

 

 

IPv4 and IPv6 VLAN Routing for Secure and Flexible Management

To help customers stay on top of their businesses, the GS-6320-24UP2T2XV not only provides ultra high transmission performance and excellent Layer 2 technologies, but also offers IPv4/IPv6 VLAN routing feature which allows to cross over different VLANs and different IP addresses for the purpose of having a highly-secure, flexible management and simpler networking application.

 

Robust Layer 2 Features

The GS-6320-24UP2T2XV can be programmed for advanced switch management functions, such as dynamic port link aggregation, Q-in-Q VLAN, Multiple Spanning Tree Protocol (MSTP), Layer 2/4 QoS, bandwidth control and IGMP/MLD snooping. The GS-6320-24UP2T2XV allows the operation of a high-speed trunk combining multiple ports. It consists of a maximum of 14 trunk groups with 4 ports for each group, and supports connection fail-over as well.

 

 

Powerful Security

The GS-6320-24UP2T2XV offers a comprehensive Layer 2 to Layer 4 access control list (ACL) for enforcing security to the edge. It can be used to restrict to network access by denying packets based on source and destination IP address, TCP/UDP port number or defined typical network applications. Its protection mechanism also comprises 802.1x Port-based and MAC-based user and device authentication. With the private VLAN function, communication between edge ports can be prevented to ensure user privacy. 

 

Enhanced Security and Traffic Control

The GS-6320-24UP2T2XV also provides DHCP Snooping, IP Source Guard and Dynamic ARP Inspection functions to prevent IP snooping from attack and discard ARP packets with invalid MAC address. The network administrator can now construct highly-secure corporate networks with considerably less time and effort than before.

 

User-friendly Secure Management

For efficient management, the GS-6320-24UP2T2XV is equipped with console, Web and SNMP management interfaces.

  • With the built-in Web-based management interface, it offers an easy-to-use, platform-independent management and configuration facility. 
  • For text-based management, it can be accessed via Telnet and the console port. 
  • For standard-based monitor and management software, it offers SNMPv3 connection which encrypts the packet content at each session for secure remote management.

 

Remote Management Solution

PLANET's Universal Network Management System (UNI-NMS) and CloudViewer app support IT staff by remotely managing all network devices and monitoring PDs' operational statuses. Thus, they're designed for both the enterprises and industries where deployments of PDs can be as remote as possible, without having to go to the actual location once a bug or faulty condition is found. With the UNI-NMS or CloudViewer app, all kinds of businesses can now be speedily and efficiently managed from one platform.

Intelligent SFP/SFP+ Diagnosis Mechanism

The GS-6320-24UP2T2XV supports SFP-DDM (Digital Diagnostic Monitor) function that greatly helps network administrator to easily monitor real-time parameters of the SFP and SFP+ transceivers, such as optical output power, optical input power, temperature, laser bias current, and transceiver supply voltage.